calibration instrument

calibration instrument
Product Detailed
1.Blue screen display, can be used all-weather. 2.Has a ferquency(Hz) measurement and emulation function.

JC-ZJF-3 process signal simulation calibration instrument is specially design for industry process control, intelligence menu prompt, digitization operation, kompleta function, 18 input, output of thermal measurement, synchronous operation, independent operation, and isolate from each other. Possess this instrument, you can easy to complete the routine maintenance and calibration.

Characteristic

Blue screen display, can be used all-weather.With the signal output and measurement of V, mV, mA, Ω and thermocouple (TC), resistance temperature (RTD).Has a ferquency(Hz) measurement and emulation function.24V DC power distribution provide the loop power for transmitter, and can measure the output value of mA form transmitter in a same time.Measure the thermocouple (resistance temperature), display rhe mV(Ω), degree celsius in a same time, not need to check the reference table any more.Using the high-precision temperature sensor to provide for cold junction compensation for thermocouple.All the signals can trimming or continuous add or subtract in arbitrary decimals.Has the function of simulation transmitter, can calibration DCS channel 4-20 mA loop current.Has RS232 comminication interface, can realize the fast revise of instrument out-of-tolerance though the PC.

 Output index

Output

Range

Resolution

Precision(%reading+%full range)

Load

Notes

Voltage(mV)

 0-±99.999

1μv

0.02%+0.015%

200Ω(min)

DC

 Voltage(V)

0-±9.9999

0.1mv

0.02%+0.02%

200Ω(min)

DC

 Current(mA)

0-±25.000

  1μA

0.02%+0.025%

20Ωless than R less than 50Ω

DC

Artificial resistance(Ω)

0-999.99

0.01Ω

0.02%+0.01%

R×1less than10V

50μAless than 1less than 10 mA

Voltage(V)

24

±10%

30mA(max)

Instrument power

 Frequency(Hz)

0-1 k

0.01Hz

0.02%+0.02%

10KΩ

TTL

resistance temperature measure and output accuracy

The type of thermocouple

 Range of measurement

The range of give accuracy(degree celsius)

      Accuracy

 Measurement

 Output

Pt100

 -50~600

-50~200

0.2

0.2

 200~600

0.25

0.2

Cu100

 -50~150

 -50~150

0.5

0.5

   Cu50

 -50~150

 -50~150

0.5

0.5

Measure index

Measure

 Range

Resolution

Accuracy(%degree+% full range)

Input impedance

 Notes

Voltage(mV)

0~±100.000

  1μV

0.02%+ 0.02%

10-9Ω

  DC

Voltage(V)

0~±10.0000

  0.1mV

 0.02%+0.25%

1MΩ

  DC

Voltage(V)

0~±50.000

   mV

0.02%+0.025%

  1MΩ

  DC

Current(mA)

0~±25.0000

  0.1μV

0.02%+0.025%

  50Ω

  DC

Resistance(Ω)

0~999.99

0.01Ω

 0.02%+0.02%

Resistance(Ω)

0~9999.9

0.1Ω

 0.02%+0.02%

Frequency(Ω)

0~10K

  0.1Hz

 0.02%+0.02%

  10KΩ

  TTL

calibration instrument