- Contact Person : Mr. wu Nicky
- Company Name : Jiangsu Jiechuang Science And Technology Co., Ltd.
- Tel : 86-517-86989540
- Fax : 86-517-86980638
- Address : Jiangsu,Huai'an,No.288,Tongtai Road,Jinhu industrial Zone,Huai'an City,Jiangsu Province
- Country/Region : China
- Zip : 211600
JC-51L intelligent radar level gauge
Place of Origin:Jiangsu China (Mainland) | Brand Name: Jiechuang | Model Number: JC-51L |
NONCONTACT: INTELLIGENT |
Packaging Detail: | Package: Cardboard box |
Delivery Detail: | within 15days after receipt of full payment |
1.Range:up to 35m 2.Temp:-40C to +250C 3.Pressure:-1.0 to +4.0Mpa 4.Accurancy:less than 0.2%(top blind zero 500mm)
JC-51L Radar Level Transmitter:
Advantages:
Non-contact measurement makes saferSimple mounting. maintenance-freeUnaffected by pressure, temperature, gas and vapourHigh measuring accuracy.
Function:Extremely short microwave pulses are emitted via the antenna system to the measured product, reflected by the product surface and received again by the antenna system. The time from emission to reception of the signals is proportional to the level. A special evaluation procedure ensures a reliable and precise measurement.
FEATURES:
Output versions: 2 wire compact transmitter with 4…20 mA and HART communication
Adjustment programming: With local display/programmer module, remote HART programming
Mounting: On top of the tank. Non-contact measurement with wave stick or horn antenna
Housing material: Aluminum cast
Material of wetted parts: Stainless steel, PTFE, PP
Operating principle: Level, volume and weight measurement calculated from distance between the sensing point and the surface
Ex approval: Yes
APPLICATION CONSIDERATIONS:
Suggested applications: Large tanks with high pressure and extreme temperatures
Measurable mediums: Electrically conductive or non-conductive (liquids, free-flowing solids) materials with min. ε>1.5 dielectric constant
Advantages: High accuracy.
Special applications: High pressure, high temperature applications
Application restrictions: Liquid hydrogen, helium and ammonia cannot be measured
TECHNICAL DATA:
Power supply: 24 V DC,
Ambient temperature:-20…+55°C
Medium temperature:-60…+250 °C flange temp.
Process pressure: ax. 64 bar
Measuring range: 40 m (100 m)
Accuracy: ± 1 mm, ± 10 mm
Output: 4…20 mA / HART
Process connection: Flange
Ingress protection: IP66
power:24VDC
JC-51L intelligent radar level gauge